Max continuous discharge current up to 110A, and available for those higher than 110A.
Gradient Current Management Method manages current drains.
High current durability with short-circuit protection greater than 2000A .
Floating shunt current mode shunts cell input current by different scales.
Mosfet grouped for managing in current surges.
Low Voltage Start Energy Reserve (LVSER): LVSER mode acts at cell volt dropping down to 2.90V, to break off lower current drains and slow down capacity loss, which is not involved with driving or igniting. The LVSER Mode is energy-saving mode to maintain margin capacity to start up the car again at its low voltage, LVSER Volt will keep dropping from 2.90V until 2.4V with load, or stay at 2.9V,while via an external switch.
No load Sleep Mode starts with no current consumption.