SPF-F-36-30 BMS

Specification

  1. With a communication port for SMBus interface via USB tool bridge to PC to gather battery information, helpful for engineering or R&M services.
  1. Monitoring battery SoC and SoH, such as amperes, volts, capacity; temperature, protection status and cell balance, cycle life times, event records etc.  
  1. With circuitry of blocking back electromotive forces(BEMF), and filter circuitry against noises or interference.
  1. Smart two-way cell balance design for both in charging and in quiescence.
  1. LED display to show battery capacity, based on Coulomb Counter and, to show protection occurrences.
  1. Key Specifications

ITEM

Unit

Min

Typical

Max

Charge

CC/CV

Standard Charging Voltage

V

 

42

 

Max Charge Current

A

 

30

 

Discharge

Discharge Voltage

V

27

 

42

Max Continuous Discharge Current

A

 

30

 

Over-Charge Protection(OVP)

OVP Detect Voltage (cell)

V

 

4.25

 

OVP Release Voltage ( cell)

V

 

4.13

 

OVP Detect Delay Time

Sec

 

2

 

Over Charge Current Protect (OCCP)>

A

 

30

 

OCCP Detect Delay Time

S

 

2

 

Under Voltage Protection(UVP)

UVP Detect Volt ( cell)

V

 

2.80

 

UVP Detect Delay Time

Sec

 

2

 

UVP Release Voltage( cell)

V

 

3.3

 

UVP Current Consumption

uA

 

700

 

UVP Shut Down Voltage

V

 

2.7

 

UVP Shut Down Current Consumption

uA

 

10

 

Discharge Protection(Adjustable)

Max Continuous Discharge Current =

A

 

30

 

Over Discharge Current Protect(ODCP)

A

31

 

65

ODCP Detect Delay Time (Adjustable)

S

 

3

 

Second ODCP( software) >

A

 

65

 

Second ODCP Detect Delay Time

mS

 

31

 

Short Circuit Protection(SCP)>=

A

 

75

 

Short Circuit Protect(SCP.) Delay Time

uS

 

550

 

Hiccup as average current remains S.C.

S

3

 

120

Release by removal condition or charging

S

 

60

 

Cell Balance

Balance Start Volt@ Delta V.>20m V or

V

 

4.10

 

Balance Release@ Delta V<20m V or

V

 

3.45

 

Balance Capability

mA

 

 

170

Over Temperature Protection(OTP)

Charge OTP when Temperature out of

0

 

55

Charge OTP Release as temp. returns in

5

 

45

Dischg OTP when temperature out of

-20

 

70

Dischg OTP Release as temp. returns in

-20

 

60

Current Consumption

Working Current Consumption in average

uA

 

700

 

Shut Down Current @ Vcel=2.0 after UVP

uA

 

10

 

Forced  Switch

Forced Switch on Mosfet (Option)

 

 

(Option)

 

Temperature

Ambient Temp.

- 20

25

45

Storage Temp.

- 20

25

80

BTS

NTC 10k+/-1% Ohm b=3435K +/-2%

 

 

 

 

Dimension

170*60*20

mm

 

 

 

Back