ITEM |
Unit |
Min |
Typical |
Max |
|
Charge CC/CV |
Standard Charging Voltage |
V |
|
54.6 |
|
Max Charge Current (default) |
A |
|
160 |
|
|
Discharge |
Discharge Voltage |
V |
38.4 |
|
57.6 |
Max Continuous Discharge Current |
A |
|
160 |
|
|
Over-Charge Protection(OVP) |
OVP Detect Voltage (cell) |
V |
|
4.23 |
|
OVP Release Voltage ( cell) |
V |
|
4..03 |
|
|
OVP Detect Delay Time |
Sec |
|
2 |
|
|
Over Charge Current Protect (OCCP) (default) |
A |
|
160 |
|
|
OCCP Detect Delay Time |
S |
|
5 |
|
|
Under Voltage Protection(UVP) |
UVP Detect Volt ( cell) |
V |
|
2.80 |
|
UVP Detect Delay Time |
Sec |
|
5 |
|
|
UVP Release Voltage( cell) |
V |
|
2.80 |
|
|
UVP Current Consumption |
uA |
|
700 |
|
|
UVP Shut Down Voltage |
V |
|
2.75 |
|
|
UVP Shut Down Current Consumption |
uA |
|
20 |
|
|
Discharge Protection (Adjustable) |
Max Continuous Discharge Current = |
A |
|
160 |
|
Over Discharge Current Protection(ODCP) |
A |
161 |
|
600 |
|
ODCP Detect Delay Time (Adjustable) |
S |
|
40 |
|
|
Second ODCP( software) > |
A |
|
600 |
|
|
Second ODCP Detect Delay Time |
mS |
|
31 |
|
|
Short Circuit Protection(SCP)>= |
A |
|
1250 |
|
|
Short Circuit Protection(SCP.) Delay Time |
uS |
|
550 |
|
|
Hiccup as detected average current remains S.C. |
S |
3 |
|
120 |
|
Release after Removing or by charging for |
S |
|
60 |
|
|
Cell Balance |
Balance Start Volts@ Delta V.>20m V or |
V |
|
3.53 |
|
Balance Release@ Delta V<20m V or |
V |
|
3.53 |
|
|
Balance Capability |
mA |
|
|
170 |
|
Over Temperature Protection(OTP) |
Charge OTP when Temperature out of |
℃ |
0 |
|
50 |
Charge OTP Release as temp. returns in |
℃ |
5 |
|
45 |
|
Dischg OTP when temperature out of |
℃ |
-20 |
|
60 |
|
Dischg OTP Release as temp. returns in |
℃ |
-10 |
|
50 |
|
Current Consumption |
Working Current Consumption in average |
uA |
|
700 |
|
Shut Down Current @ Vcel=2.0 after UVP |
uA |
|
20 |
|
|
Temperature |
Ambient Temp. |
℃ |
- 20 |
25 |
45 |
BTS |
NTC 10k+/-1% Ohm b=3435K +/-2% |
|
|
|
|
Dimension |
218mm*160mm*28mm |
mm |
|
|
|